List of Holding Registers
Network Data
Func.
Code
Name R/W Description
Reg. Range Res.
C144 Terminal [11] ON delay R/W Range is 0.0 to 100.0 sec. 1153h 0 to 1000 0.1 sec
C145 Terminal [11] OFF delay R/W Range is 0.0 to 100.0 sec. 1154h 0 to 1000 0.1 sec
C148 Output relay ON delay R/W Range is 0.0 to 100.0 sec. 1157h 0 to 1000 0.1 sec
C149 Output relay OFF delay R/W Range is 0.0 to 100.0 sec. 1158h 0 to 1000 0.1 sec
Note 1: Assume that the inverter current rating is 10000 (for C041).
The following table lists the holding registers for the “H” Group Motor Constants.
List of Holding Registers
Network Data
Func.
Code
Name R/W Description
Reg. Range Res.
H003 Motor capacity R/W 1165h 0 to 13
H203 Motor capacity, 2nd
motor
R/W
0…0.20kW
1…0.37kW
2…0.40kW
3…0.55 kW
4…0.75 kW
5…1.10 kW
6…1.50 kW
7…2.2 kW
8…3.0 kW
9…3.7 kW
10…4.0 kW
11…5.5 kW
12…7.5 kW
13…11.0kW
1541h 0 to 13
H004 Motor poles setting R/W 1166h 2, 4, 6, 8 1 pole
H204 Motor poles setting, 2nd
motor
R/W
Four selections:
2 / 4 / 6 / 8
1542h 2, 4, 6, 8 1 pole
H006 Motor stabilization
constant
R/W 1168h 0 to 255 1
H206 Motor stabilization
constant, 2nd motor
R/W
Motor constant (factory set),
range is 0 to 255
1544h 0 to 255 1
B39
Appendix B
B 39
Appendix B