Lincoln Electric DC-655 Soldering Gun User Manual


 
SEMIAUTOMATIC WIRE FEEDERS
CONNECTING THE LN-7 TO THE IDEALARC
DC-655 (14-PIN MS RECEPTACLE)
1. Set the POWER toggle switch to the OFF (0) posi-
tion.
2. Disconnect main AC input power to the Idealarc
DC-655.
3. Connect the electrode cable from the control
cable to the “+” terminal of the welder and to the
LN-7 wire feeder. Connect the work cable to the
“-” terminal of the welder (High inductance or low
inductance as needed). Reverse this hookup for
negative polarity.
NOTE: Welding cable must be sized for the current
and duty cycle of the application.
4. Connect control cable between the DC-655 and
the LN-7. See Figure C.3.
5. Set the MODE switch to a CV (constant voltage)
position at the welder.
6. Adjust wire feed speed at the LN-7 and set the
welding voltage with the output CONTROL.
NOTE: If optional remote control is used, place the
OUTPUT CONTROL and the OUTPUT TERMI-
NALS switch in the “Remote” position.
ACCESSORIES
C-6 C-6
IDEALARC DC-655
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
41
4231
32
75 76
77
NEGATIVE
POSITIVE
32
31
2
4
GND
21
ELECTRODE CABLE
TO WIRE FEED UNIT
TO WORK
}
POWER SOURCE
LN-7 TO INPUT
CABLE PLUG
LN-7 CONTROL
CABLE
21
-
21
21
+
REMOTE VOLTAGE SENSING LEAD
FIGURE C.3
IDEALARC DC-655/LN-7 WITH K584 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM