Baldor mn1854 Power Screwdriver User Manual


 
Receiving & Installation 3-7MN1854
RS232 PC Connections
A null modem connection must be made between the LinStep+ and the computer
COM port. This will ensure that the transmit and receive lines are properly
connected. Either a 9 pin or a 25 pin connector can be used at the computer,
Figure 3-6. Maximum recommended length for RS232 cable is 6 ft. (1.8 meter).
Figure 3-6 9 & 25 Pin RS-232 Cable Connections for UL Installations
25 Pin Connector
9 Pin Connector
Pin
Signal
2 RXD
3 TXD
7 GND
Pin
Signal
2 RXD
3 TXD
5 GND
LinStep+
(DCE)
Computer
COM
Port
(DTE)
RXD 4
TXD 5
Com 6
RXD
TXD
GND
RS232 Connector
Chassis
If required, RTS, CTS, DSR and DTR may also
be connected for a full null modem connection.
Jumper
9 Pin 25 Pin
RTS to CTS
DSR to DTR
7 to 8
4 to 6
4 to 5
6 to 20
Tx
Com
N/A
Rx
N/A
N/A
Connector location is
shown in Figure 3-4.