Setup 5-5MN1854
Configuring Position Maintenance Max Velocity [ PVi ]
EDIT
> SETUP > ENC > PMMAX
Value: 1.0 in/s
Range: 0.0059,999,999.0
Axis One PM MaxVel
1.0 in/s
Limits the velocity of a position maintenance correction. Regardless
of the magnitude of displacement of correction gain, the correction
velocity will never exceed this maximum velocity setting.
Select value, press ENTER
Press or to select next axis.
Configure Your Application (Mechanics)
The MECH SETUP menu allows you to preset distance, velocity, and acceleration
units convenient for your application. These units are used for all display and
position reporting modes. This menu also allows you to compensate for a known
amount of backlash in your mechanical system, and to set a maximum allowable
speed for each axis.
Action
Display Comments
Press EDIT key
EDIT
PROG SETUP POS
Select a submenu, press F1 (PROG),
F2 (SETUP), or F3 (POS).
Press F2 (SETUP) key for more
sub menu selections. Press key
for more sub menu selections.
SETUP
PROG RS232 MISC
Select a submenu, press F1 (PROG),
F2 (RS232), or F3 (MISC).
Press F3 (MECH) key
SETUP
MOTOR ENC MECH
Select a submenu, press F1
(MOTOR), F2 (ENC), or F3 (MECH).
Press key for more sub menu
selections.
←↑ MECH SETUP ↓→
DIST Pitch Vel
Select a submenu, press F1
(Distance), F2 (Pitch), or
F3 (Velocity).
Press key for more sub menu
selections.
←↑ MECH SETUP ↓→
VMAX ACCEL AMAX
Select a submenu, press F1 (VMAX),
or F2 (Accel), or F3 (AMAX).
Configuring the Distance Unit [ DUi ]
EDIT
> SETUP > MECH > DIST
Value: inch
Range: inch or mm
Axis One Dist Units
←↑ inch ↓→
This sets the distance units and unit label. All distance values are
expressed in the units selected here.
or to select value, press ENTER