5-14 Setup MN1854
Configuring Homing Mode [ HMi ]
EDIT
> SETUP > HOME > MODE
Value: Switch Only
Range: Switch Only
–Axis One Home Mode–
←↑ Switch Only ↓→
Sets how a Go Home (GH) command will execute. The control will
only search for the appropriate edge of a switch.
Only one selection available.
Press ← or → to select next axis.
Configuring Home Edge [ HEi ]
EDIT
> SETUP > HOME > EDGE
Value: NEGATIVE
Range: NEGATIVE, POSITIVE
– Axis One Home Edge –
← NEGATIVE →
Sets the home switch active on the negative edge or positive edge
of the encoder index channel. Use the ← and → keys to select.
Select value, press ENTER
Press ← or → to select next axis.
Configuring Home Switch [ HSi ]
EDIT
> SETUP > HOME > SWITCH
Value: Norm Open
Range: Norm Open or Norm Closed
–Axis One Home Switch–
← Norm Open →
Selects the type of switch used for the home input. Use the ← and
→ keys to select.
Select value, press ENTER
Press ← or → to select next axis.
Configuring Home Offset [ HOr ]
EDIT
> SETUP > HOME > OFFSET
Value: 0.0 {Distance Units}
Range: 0.0–999,999,999.0
–Axis One Home Offset–
← 0.0 in →
Sets the offset from home position for the “real” home position. After
a successful homing move, the home position (the factory set home
position is +0.0000) is set to the offset value. Use the numeric keys
to enter a value.
This allows multiple systems to have identical programs and only
change the home offset value for each machine.
Select value, press ENTER
Press ← or → to select next axis.