5-6 Setup MN1854
Configuring Units of Velocity [ VUi ]
EDIT
> SETUP > MECH > VEL
Value: in/s
Range: in/s or in/min
– Axis One Vel Units –
←↑ in/s ↓→
Sets the velocity units. All velocity values will be expressed in these units.
↑ or ↓ to select value, press ENTER
Press ← or → to select next axis.
Configuring Maximum Velocity [ MVr ]
EDIT
> SETUP > MECH > VMAX
Value: 500.0 in/s
Range: 0–9999999.0
– Axis One MAX Vel –
←↑ 500.0 in/s ↓→
Sets the top speed of your motor. (Limits the speed from LinStep+ to
prevent accidental damage to your mechanics.)
Select value, press ENTER
Press ← or → to select next axis.
Configuring Acceleration Units [ AUi ]
EDIT
> SETUP > MECH > ACCEL
Value: in/s
2
Range: seconds or in/s
2
– Axis One Accel Units –
←↑ in/s
2
↓→
Sets the acceleration (and deceleration) units. All acceleration and
deceleration values will be expressed in these units. You can specify
acceleration as a rate, or in time–to–accelerate to full speed.
↑ or ↓ to select value, press ENTER
Press ← or → to select next axis.