Baldor mn1854 Power Screwdriver User Manual


 
Keypad Programming 6-9MN1854
Value: N/A
Units: set in EDIT > SETUP > MECH > ACCEL > VEL
Range: Unit scaling dependent
Initiates a homing routine (seeks the home switch) to establish a home reference position. When it reaches
home, the position counter is set to zero or to the Home Offset (HO) value selected in the EDIT > SETUP > HOME
menu. The motor will move at the GH velocity (n) and direction (±) specified until it either finds a home limit switch
or determines that it can not find one between the two endoftravel limit switches. The Go Home move uses
the last acceleration and deceleration specified.
The exact homing routine used, and the ultimate end position of your systems home reference, depends on the
values of your EDIT > SETUP > HOME parameters (edge, level, final approach direction, and offset) and if you
have specified open or closed loop moves in the EDIT > SETUP > ENCODER menu. The control will reverse
direction when the first End of Travel limit switch is encountered while searching for a Home switch. If the second
End of Travel switch is encountered, the unit will abort the Go Home move and generate a fault. Assuming the
presence of an operational home switch, the control will seek a home position according to the parameters you
specified (edge, level, final approach direction, and offset).
Closed loop systems will normally home with more accuracy than open loop systems because encoders have
a Z marker pulse. In a typical Go Home routine, the control will first sense the edge of the switch defined in the
Go Home SETUP menu. It will then decelerate the motor to a stop at the last defined deceleration rate. The final
homing motion is determined by the Go Home options selected in the SETUP menu. The final homing direction
dictates the direction from which the final approach to the switch is made. The edge selected will determine
which side of the home switch this final approach will be based from.
In a closed loop mode Go Home routine, the control will additionally slow to a creep speed and stop when it
sees the encoders Z Marker Pulse after seeing the reference edge of the switch. If a marker pulse is not seen
within one motor revolution after the reference edge of the switch is seen, the final homing routine will be aborted.
Note: Homing Mode directly affects or reconfigures the function of the GH command.
Examples:
AC.5 DE.5 GH
20 Go Home in the negative direction at a speed of 20
AC.5 DE.5 GH
20 Axis one Go Home in the positive direction at a speed of 20.
GH
Start Home syntax GH±r