Baldor mn1854 Power Screwdriver User Manual


 
8-2 Specifications & Product Data MN1854
General Specifications
Description Unit LX2P1A062
Input Voltage Range Nominal
Minimum
Maximum
VAC 115
92
132
Input Frequency Hz 50/60 ±5%
Nominal Output Bus Nominal
(@ 115 / 230 input) Minimum
Maximum
VDC 170
88
220
Max. Output Current each axis
A
RMS
6
Resolution in (mm) 4 x 10
5
(1.016 x 10
3
)
Efficiency % 85
Motor Inductance mH 2 60
Switching Frequency kHz 20
Encoder Optically Isolated, differential line driver, 5VDC, 500 KHz Max (2
MHz post quadrature)
Inputs 8 Programmable + 2 Limit and 1 Home inputs. (24VDC
maximum optically isolated 3mA sink current at 0.7Volts)
Output Power 12VDC @ 12mA (Pullups)
5VDC @ 200mA (encoder)
Programmable Outputs 8 Open collector (100mA maximum sink current,
350mA maximum total sink amps).
Programming Keypad or Serial communications
Operating Temperature
°F 〈°C)
32 to 100 (0 to 40); 122 (50) Maximum
Operating Altitude ft (m) 8300 (2540) Maximum
Storage Temperature
°F 〈°C)
13 to 158 (25 to 70)
Humidity (noncondensing) % 1090
Shock 10G (according to DIN IEC 6826/29)
Vibration 1G @ 10 150 Hz (according to DIN IEC 6826/29)
Protection & Indicators Description
LED Indications Green Normal operation; Red Fault condition; Amber FLASH
fault Protection
Short Circuit Disable on phasetophase, or phasetoground detected
Undervoltage Disable if supply drops below 90 VAC
Over Temperature Disable if heatsink > 70 °C
Interlock Disable if interlock connection broken
Regen/Overvoltage Disable if bus voltage exceeds 220 VAC on 115 VAC units, 440 VAC
on 230 VAC unit