Setup 5-15MN1854
Configuring Home Direction [ HFi ]
EDIT
> SETUP > HOME > DIR
Value: POSITIVE
Range: NEGATIVE, POSITIVE
–Axis One Final Dir–
← Positive →
Sets the direction for the Go Home (GH) move. This is the direction used to
search for the encoder index mark (Z channel) after the appropriate home
switch edge is found.
Select value, press ENTER
Configure Power–up Program
The Program Setup menu allows selection of (1) a program to be immediately run
when LinStep+ is powered–up and (2) scanning conditions for the BCD or binary
program select inputs.
Action
Display Comments
Press F1 (PROG) key for more
sub menu selections.
–↑SETUP↓–
PROG RS232 MISC
Select a sub–menu, press F1 (PROG),
F2 (RS232), or F3 (MISC).
Configuring Power–up Program [ PUi ]
EDIT
> SETUP > PROG > PWR–UP
Value: 0
Range: 0–400
– Power Up Program –
PROGRAM:0
Sets the program to run at power–up. The selected program is
executed (run) when power is applied or after a reset. If a value of 0
is entered in this menu, or if the specified program does not exist, no
program is run. Use numeric keys to enter program number.
Select value, press ENTER
Configuring Scan Conditions [ SNaaaaaaaa ]
EDIT
> SETUP > PROG > SCAN
Value: YYYYYYY
Range: YYYYYYY, NNNNNNN
– Stop After Scan –
←↑ Y
YYYYYY ESC ↓→
Selects the events that cause the control to stop scanning program–select
configured inputs. The selected event is listed to the right of these 7
characters: ESCape, STOP, LIMIT+, LIMIT–, KILL, FAULT or INTerrupt.
If a stop–scan event is enabled, the system will stop scanning the inputs for
program numbers when that condition occurs. To resume scanning, a reset
(Warm Boot input or cycle power Off then On) must be given. This option
has no effect if the inputs are not configured as program select inputs (either
BCD or Binary).
Select value, press ENTER