6-22 Administrative Products for DB2 Installation Guide
Default Option Descriptions
UBSTP The DASD MANAGER PLUS load library. If you are installing DASD
MANAGER PLUS together with CATALOG MANAGER, type the name of
the DASD MANAGER PLUS load library. Otherwise, comment out the
library name.
Note: These parameters must match the load library and options module
name that is used when installing DASD MANAGER PLUS. See
also the description for BOPTS.
UCDSP='&&PREFIX..&&SID..&&OBNOD'
The prefix to be used with the last qualifier of SYSCOnnn data sets. The
&&OBNOD symbolic variable resolves to database.&SPNAME. &SPNAME
resolves to a table space name or to an index space name, depending on the
type of object that is being copied.
UCOMD (optional) The user command table.
UCSTP The name of the COPY PLUS product’s load library. If you are installing
COPY PLUS together with CATALOG MANAGER, type the name of the
COPY PLUS load library. Otherwise, comment out the library name.
UDEVT=SYSDA The name of the copy device type.
UDSTP The DATA PACKER load library. If you are installing DATA PACKER
together with CATALOG MANAGER, type the name of the DATA PACKER
load library. Otherwise, comment out the library name.
UESTP The DATA PACKER EDITPROC load library.
UJC1='//&&USERID.&&JOBCHAR JOB (ACCT),''&&PGMR'','
UJC2='// CLASS=A, MSGCLASS=X, MSGLEVEL=(1,1),'
UJC3='// NOTIFY=&&USERID'
UJC4='//*'
UJC5='//*'
Five default job statements for your installation. Set unused statements to
comments (//*) or null.
UKSTP The CHECK PLUS product’s load library. If you are installing CHECK
PLUS together with CATALOG MANAGER, type the name of its load
library. Otherwise, comment out the library name.