GFCI RECEPTACLE TESTING AND RESET-
TING PROCEDURE
The GFCI receptacle should be properly tested at least
once every month or whenever it is tripped. To proper-
ly test and reset the GFCI receptacle:
• If the receptacle has tripped, first carefully remove
any load and check it for damage.
• If the equipment has been shut down, it must be
restarted.
• The equipment needs to be operating at high idle
speed and any necessary adjustments made on the
control panel so that the equipment is providing at
least 80 volts to the receptacle input terminals.
• The circuit breaker for this receptacle must not be
tripped. Reset if necessary.
• Push the "Reset" button located on the GFCI recep-
tacle. This will assure normal GFCI operation.
• Plug a night-light (with an "ON/OFF" switch) or other
product (such as a lamp) into the GFCI receptacle
and turn the product "ON".
• Push the "Test" button located on the GFCI recepta-
cle. The night-light or other product should go "OFF".
• Push the "Reset" button, again. The light or other
product should go "ON" again.
If the light or other product remains "ON" when the
"Test" button is pushed, the GFCI is not working prop-
erly or has been incorrectly installed (miswired). If your
GFCI is not working properly, contact a qualified, certi-
fied electrician who can assess the situation, rewire the
GFCI if necessary or replace the device.
SPARK ARRESTOR
For machines with separate spark arresting unit:
Service the spark arrestor every 100 hours of opera-
tion or twice a year, which ever occurs first.
Service as follows:
1. Stop engine and allow to cool.
2. Loosen clamp and remove spark arrestor from
machine.
3. Remove locknut on top of spark arrestor housing
and lift off cap.
4. Seperate plates and clean if necessary.
5. Inspect plates and housing for holes or cracks.
Replace spark arrestor if damaged.
6. Assemble spark arrestor using reverse order:
step 3, then step 2.
For machines with integral spark arresting muf-
flers:
Service spark arrestor every 250 hours.
Service as follows:
1. Stop engine and allow to cool.
2. Remove clean out plug from the side of the spark
arrestor.
3. Without damaging the spark arrestor, gently tap on
the shell near the clean out plug.
4. Once particles are removed, replace the clean out
plug.
WARNING
Allow engine to cool before
Do not operate engine while
servicing spark arrestor!
servicing spark arrestor!
Spark Arrestor and Muffler may be hot!