Lincoln Electric SVM187-A Welder User Manual


 
THEORY OF OPERATION
E-5 E-5
SAE-400 SEVERE DUTY
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
EXCITER/AUXILIARY ALTERNATOR
OPERATION (Continued)
AC Auxiliary Output:
The exciter alternator is now producing sufficient AC
power from both the exciter winding and the 115/230
VAC auxiliary power winding. This 115/230 VAC, 60
Hz. auxiliary power is made available for use through
the receptacles on the front panel of the machine, after
passing through circuit breakers and the automatic idle
system’s current sensor.