Lincoln Electric SVM187-A Welder User Manual


 
EXCITER COVER
FIVE SCREWS
(TWO ON OTHER SIDE)
FIGURE F.8 – EXCITER COVER SCREW LOCATIONS
EXCITER ROTOR RESISTANCE AND GROUND TEST
(Exciter / Auxiliary Power Alternator) (continued)
PROCEDURE
“Static” Tests:
1. Turn the engine off.
2. Open either, or both of the doors on the control
panel end of the SAE-400 machine.
WARNING: Secure the doors in the open position
using the door restraint system. If the
machine does not have a door restraint
system, remove the doors or securely
restrain them to prevent them from falling
closed.
3. Remove the cover from the exciter / auxiliary power
alternator by removing the screws securing it. See
Figure F.8.
4. Locate and label the leads connected to the rotor
brush holder assembly. Remove the leads.to elec-
trically isolate the rotor windings.
TROUBLESHOOTING AND REPAIR
F-34 F-34
SAE-400 SEVERE DUTY
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC