• System Health
• Storage
• Configuration
• Audit
• Updates
3. Select one or more of the following severity levels:
• Critical
• Warning
• Informational
The Monitored Alerts section displays the results based on the selected category and severity. For
information about the field descriptions on the this page, see the Online Help.
4. Click Apply.
Setting Event Alerts Using RACADM
To set an event alert, run the eventfilters command. For more information, see the Chassis
Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide
available at
dell.com/support//manuals.
Configuring Alert Destinations
The management station uses Simple Network Management Protocol (SNMP) to receive data from CMC.
You can configure the IPv4 and IPv6 alert destinations, email settings, and SMTP server settings, and test
these settings.
Before configuring the email alert or SNMP trap settings, make sure that you have the Chassis
Configuration Administrator privilege.
Configuring SNMP Trap Alert Destinations
You can configure the IPv6 or IPv4 addresses to receive the SNMP traps.
Configuring SNMP Trap Alert Destinations Using CMC Web Interface
To configure IPv4 or IPv6 alert destination settings using CMC Web interface:
1. In the left pane, click Chassis Overview → Alerts → Trap Settings.
2. On the Chassis Event Alert Destinations page, type the following:
• In the Destination field, type a valid IP address. Use the quad-dotted IPv4 format, standard IPv6
address notation, or FQDN. For example: 123.123.123.123 or 2001:db8:85a3::8a2e:370:7334 or
dell.com.
Choose a format that is consistent with the networking technology or infrastructure. The Test
Trap functionality cannot detect incorrect choices based on the current network configuration
(example, use of an IPv6 destination in an IPv4-only environment).
• In the Community String field, enter a valid community name to which the destination
management station belongs.
This community string differs from the community string on the Chassis Overview → Network →
Services page. The SNMP traps community string is the community that CMC uses for outbound
115