15
Managing Chassis Storage
On the Dell PowerEdge VRTX, you can perform the following operations:
• View the status of physical disks drives and storage controllers.
• View the properties of controllers, physical disk drives, virtual disks, and enclosures.
• Set up controllers, physical disk drives, and virtual disks.
• Assign virtual adapters.
• Troubleshoot controller, physical disk drives, and virtual disks.
• Update storage components.
• Use the shared storage controllers in fault-tolerant mode
• Enabling or disabling Shared PERC8 (Integrated 2)
Viewing Status of the Storage Components
To view the status of the storage components:
1. In the left pane, click Chassis Overview → Storage → Properties → Storage Overview.
2. On the Storage Overview page, you can:
• View the graphic summary of the physical disk drives installed in the chassis and their status.
• View the summary of all the storage components with links to their respective pages.
• View the used capacity and total capacity of the storage.
• View controller information.
NOTE: In case of a fault-tolerant controller, the name format is: Shared <PERC number>
(Integrated <number>). For example, the active controller is Shared PERC8 (Integrated 1)
and the peer controller is Shared PERC8 (Integrated 2).
NOTE: If the secondary PERC is disabled, the name is displayed as Disabled PERC
(Integrated 2).
• View recently-logged storage events.
NOTE: For more information, see the Online Help.
Viewing the Storage Topology
To view the Storage topology:
1. In the left pane, click Chassis Overview → Storage → Properties → Topology.
2. On the Topology page, click the <controller name> to view the respective pages.
191