Dell 2 Biscuit Joiner User Manual


 
images (DUP) may be available in optimized forms, where a single DUP may be programmed to
update multiple types or models of devices of a given category.
Filtering Components for Firmware Updates Using CMC Web Interface
To filter the devices:
1. In the left pane, go to Server Overview, and then click Update .
2. On the Server Component Update page, in the Component/Device Update Filter section, select
one or more of the following:
BIOS
iDRAC
Lifecycle Controller
32-Bit Diagnostics
OS Driver Pack
Network I/F Controller
RAID Controller
The Component/Device Update Filter section is displayed only for the Update by File mode of
firmware update.
The Firmware Inventory section displays only the associated components or devices across all
servers present in the chassis. After you select an item from the drop-down menu, only the
components or devices associated with the ones in the are list displayed.
After the filtered set of components and devices is displayed in the inventory section, further filtering
may occur when a component or device is selected for update. For example, if the BIOS filter is
selected, then the inventory section displays all the servers with only their BIOS component. If a BIOS
component on one of the servers is selected, the inventory is further filtered to display the servers
that match the model name of the selected server.
If a filter is not selected and a selection for update of a component or device is made on the
inventory section, then the filter associated with that selection is automatically enabled. Further
filtering may occur where the inventory section displays all the servers that have a match for the
selected component in terms of model, type, or some form of identity. For example, if a BIOS
component on one of the servers is selected for update, the filter is automatically set to the BIOS and
the inventory section displays the servers that match the model name of the selected server.
Filtering Components for Firmware Updates Using RACADM
To filter components for Firmware Updates using RACADM, run the getversion command:
racadm getversion -l [-m <module>] [-f <filter>]
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command
Line Reference Guide available at dell.com/support/manuals.
Viewing Firmware Inventory
You can view the summary of the firmware versions for all components and devices for all servers
currently present in the chassis along with their status.
60