Dell 2 Biscuit Joiner User Manual


 
Ite
m
Indicator, Button, or
Connector
Description
7 Information tag A slide-out label panel which allows you to record system
information such as Service Tag, NIC, MAC address, the system's
electrical rating, and Worldwide Regulatory Agency marks.
8 Optical drive (optional) One optional SATA DVD-ROM drive or DVD+/-RW drive.
9 Vents Vents for the temperature sensor.
NOTE: To make sure about proper cooling, verify that the
vents are not blocked.
10 Video connector Allows a monitor to be connected to the system.
11 Server modules Up to four PowerEdge M520, M620, or M630 server modules or 2
M820 server modules specifically configured for the enclosure.
Minimum CMC Version
The following table lists the minimum CMC version required to enable the listed server modules.
Table 1. Minimum CMC Version for server modules
Servers Minimum version of CMC
PowerEdge M520 CMC 1.36
PowerEdge M620 CMC 1.36
PowerEdge M820 CMC 1.36
PowerEdge M630 CMC 2.00
The following table lists the minimum CMC version required to enable the listed I/O moduless.
Table 2. Minimum CMC Version for I/O modules
IOM Switches Minimum version of CMC
R1 VRTX 1Gb Pass-through CMC 1.20
R1-2401 ROBO 1Gb Switch Module CMC 1.20
R1-2210 VRTX 10Gb Switch CMC 2.00
Supported Remote Access Connections
The following table lists the supported Remote Access Controllers.
Table 3. Supported Remote Access Connections
Connection Features
CMC Network Interface ports
GB port: Dedicated network interface for the CMC web interface.
DHCP support.
SNMP traps and e-mail event notification.
Network interface for the iDRAC and I/O Modules (IOMs).