178 IBM 9077 SP Switch Router: Get Connected to the SP Switch
7. On the CWS of SP21, check if the SP Switch Router Adapter card is
configured. To perform this check, look if the SP Switch Router Adapter
card shows up green in perspectives or enter
SDRGetObjects
switch_responds
. Use Eunfence if needed.
8. Issue some
ping commands to check the connection:
On the chosen SP21 nodes,
ping all four FDDI interfaces of the nodes in
SP2, for example:
On node 9-12 in SP2,
ping the SP Switch interfaces of the chosen nodes
in SP21, for example:
/root netstat -in
Name Mtu Network Address Ipkts Ierrs Opkts Oerrs Coll
de0 1500 <link1> 00:c0:80:96:38:68 10290 0 42228 0 182
de0 1500 <Bridge> 00:c0:80:96:38:68 10290 0 42228 0 182
de0 1500 192.168.4 192.168.4.4 10290 0 42228 0 182
rmb0 616 <link2> 00:00:00:00:00:00 170556 74 41439 0 0
rmb0 616 <GRIT> 0:0x40:0 170556 74 41439 0 0
lo0 1536 <link3> 8387 0 8387 0 0
lo0 1536 127 127.0.0.1 8387 0 8387 0 0
lo0 1536 <GRIT> 0:0x48:0 8387 0 8387 0 0
gf000 4352 <link10> 00:c0:80:89:2d:f2 19 0 20 0 0
gf000 4352 10.2.1/24 10.2.1.15 19 0 20 0 0
gf001 4352 <link20> 00:c0:80:89:2d:f3 12 0 12 0 0
gf001 4352 10.3.1/24 10.3.1.16 12 0 12 0 0
gf002 4352 <link11> 00:c0:80:89:2d:f4 13 0 13 0 0
gf002 4352 10.4.1/24 10.4.1.17 13 0 13 0 0
gf003 4352 <link12> 00:c0:80:89:2d:f5 13 0 19 0 0
gf003 4352 10.5.1/24 10.5.1.18 13 0 19 0 0
root@sp21n01:/ ping 10.2.1.12
PING 10.2.1.12: (10.2.1.12): 56 data bytes
64 bytes from 10.2.1.12: icmp_seq=0 ttl=254 time=10 ms
64 bytes from 10.2.1.12: icmp_seq=1 ttl=254 time=1 ms
^C
----10.2.1.12 PING Statistics----
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 1/5/10 ms
root@sp2n12:/ ping 192.168.14.1
PING 192.168.14.1: (192.168.14.1): 56 data bytes
64 bytes from 192.168.14.1: icmp_seq=0 ttl=254 time=1 ms
64 bytes from 192.168.14.1: icmp_seq=1 ttl=254 time=1 ms
^C
----192.168.14.1 PING Statistics----
2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max = 1/1/1 ms