Lincoln Electric SVM145-B Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-95 F-95
COMMANDER 300
WARNING
STATOR/ROTOR REMOVAL AND REPLACEMENT
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
The following procedure will aid the technician in removing and replacing the Commander
300 stator and rotor.
MATERIALS NEEDED
3/8" Wrench Slot head screw driver
7/16" Wrench Phillips head screw driver
1/2" Wrench Gear puller (small)
3/4" Wrench Hoist
1" Open end wrench Feeler gauge (for air gap check)
1-1/8" Wrench
This procedure should take approximately 5
1