Lincoln Electric SVM145-B Welder User Manual


 
CONNECTION OF THE LN-7 TO THE
COMMANDER 300 USING K867
UNIVERSAL ADAPTER (SEE FIGURE C.1.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-7 to the
“+” terminal of the welder. Connect the work cable
to the “-” terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
NOTE: Figure C.1 shows the electrode connected for
positive polarity. To change polarity, shut the welder off
and reverse the electrode and work cables at the
Commander 300 output terminals.
3. Connect the K867 Universal Adapter to the K291
or K404 input cable and the 14-pin amphenol of the
Commander 300 as indicated in Figure C.1. Make
the proper connections for local or remote control
according to Figure C.1.
4. Connect the K291 or K404 input cable to the LN-7.
5. Place the IDLER switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control cir-
cuits may be damaged. The engine governor setting is
preset at the factory—do not adjust above RPM speci-
fications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE” if
a K775 remote control is used. Set the switch to
“LOCAL” if no remote control is used.
7. Set the VOLTMETER switch to “+” or “-” depend-
ing on the polarity chosen.
8. Set the OUTPUT RANGE switch to “WIRE
WELDING CV.”
9. Set the WELDING TERMINALS switch to
“WELDING TERMINAL REMOTELY CON-
TROLLED.”
10. Adjust wire feed speed at the LN-7.
11. Adjust the ARC CONTROL to the desired level
(“soft” or “crisp”).
ACCESSORIES
C-4 C-4
COMMANDER 300
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CAUTION
FIGURE C.1
COMMANDER 300/LN-7 WITH K867 ADAPTER CONNECTION DIAGRAM
GND
75
76
77
GREEN
K291 OR K404
75
INPUT CABLE
76
77
K775 OPTIONAL
REMOTE CONTROL
81
42
41
31
31
32
32
2
2
4
4
21
21
GND
82
LN-7
WIRE
FEEDER
SPARE
+
ELECTRODE CABLE
TO WIRE FEED UNIT
K867 UNIVERSAL
ADAPTER PLUG
14 PIN
AMPHENOL
TO WORK