Lincoln Electric SVM145-B Welder User Manual


 
CONNECTION OF THE LN-8 TO THE
COMMANDER 300 USING K595 INPUT
CABLE ASSEMBLY (SEE FIGURE C.4.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-8 to the
“+” terminal of the welder. Connect the work
cable to the “-” terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
NOTE: Figure C.4 shows the electrode connected for
positive polarity. To change polarity, shut the welder
off and reverse the electrode and work cables at the
Commander 300 output terminals.
3. Connect the K595-XX Input Cable Assembly to the
LN-8.
4. Connect the K595-XX to the 14-pin amphenol on
the Commander 300.
5. Place the IDLER switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set
ting is preset at the factory—do not adjust above RPM
specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE.”
7. Set the VOLTMETER switch to “+” or “-” depend-
ing on the polarity chosen.
8. Set the OUTPUT RANGE switch to “WIRE
WELDING CV.”
9. Set the WELDING TERMINALS switch to
“WELDING TERMINALS REMOTELY CON-
TROLLED.”
10. Adjust wire feed speed and voltage at the LN-8.
11. Adjust the ARC CONTROL to the desired level
(“soft” or “crisp”).
ACCESSORIES
C-7 C-7
COMMANDER 300
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CAUTION
FIGURE C.4
COMMANDER 300/LN-8 WITH K595 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM
TO LN-8 INPUT
CABLE PLUG
AMPHENOL
ELECTRODE CABLE
TO WORK
14 PIN
K595 INPUT CABLE ASSEMBLY
TO WIRE FEED UNIT
+