E6581301
F-3
6
6.2 Input signal selection
6.2.1 Priority when forward/reverse run commands are entered simultaneously
H
HH
H : Priority when forward/reverse run commands are entered
simultaneously
• Function
This parameter allows you to select the direction in which the motor runs when a forward run (F) command
and a reverse run (R) command are entered simultaneously.
1)Reverse run
2)Deceleration stop
[Parameter setting]
Title Function Adjustment range Default setting
H
Priority when forward/reverse run
commands are entered
simultaneously
:Reverse run, :Stop
Output frequency [Hz]
Forward run
Reverse run
Forward run signal
Reverse run signal
ON
OFF
ON
OFF
If a F command and a R command are entered simultaneously,
the motor will run in the reverse direction.
0
Set frequency
Set frequency
Time [s]
[H=(Reverse run)]
Forward run signal
Reverse run signal
Output frequency [Hz]
Set frequency
Forward run
Reverse run
ON
OFF
ON
OFF
If a F command and a R command are entered simultaneously
the motor will slow down to a stop.
Time [s]
0
[
H
=
(Stop)]