Toshiba VF-AS1 Welding System User Manual


 
K-7
E6581301
11
[4] Terminal response time setup Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vect
or control
PM
control
V/f Reference
Speed
control
Torque
control
H
0140
Input terminal 1 response time
selection
(F)
2~200ms 1/1 8 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 3
H
0141
Input terminal 2 response time
selection
(R)
2~200ms 1/1 8 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 3
H
0142
Input terminal 3 response time
selection
(ST)
2~200ms 1/1 8 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 3
H
0143
Input terminal 4 response time
selection
(RES)
2~200ms 1/1 8 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 3
H
0144
Input terminal 5~12 respon
se
time selection
2~200ms 1/1 8 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 3
H
0145
Input terminal 13~20 response
time selection
5~200ms 1/1 8 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 3
H
0164
Input terminal selection 17(B12)
0~1
5
5
*1
1/1
0
Disabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
7. 2. 1
H
01
65
Input terminal selection 18(B13)
0~1
5
5
*1
1/1
0
Disabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
7. 2. 1
H
0166
Input terminal selection 19(B14)
0~1
5
5
*1
1/1
0
Disabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
7. 2. 1
H
0167
Input terminal selection 20(B15)
0~1
5
5
*1
1/1
0
Disabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
7. 2. 1
H
0168
Output terminal function
selection 10
(R3)
*5
0~255 *2 1/1 254 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 2
H
0169
Output terminal function
selection 11
(R4)
*5
0~255 *2 1/1 254 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 7. 2. 2
H
0170
Base frequency 2
25.0~
500 Hz
0.1/0.01
*
4
Disabled
-
-
-
Ɣ
6. 4. 1
H
0171
Base frequency voltage 2
50~330V/660V
1/0.1
*
3
Disabled
-
-
-
Ɣ
6. 4. 1
H
0172
Manual torque boost 2
0.0~30.0%
0.1/0.1
*
3
Enabled
-
-
-
Ɣ
6. 4. 1
H
0173
Thermal protection level
2
10~100%
1/1
100
Enabled
-
-
-
Ɣ
6. 4. 1
H
0174
Base frequency 3
25.0~
500 Hz
0.1/0.01
*
4
Disabled
-
-
-
Ɣ
6. 4. 1
H
0175
Base frequency voltage 3
50~330V/660V
1/0.1
*
3
Disabled
-
-
-
Ɣ
6. 4. 1
H
0176
Manual torque boost 3
0.0~30.0%
0.1/0.1
*
3
Enabled
-
-
-
Ɣ
6. 4. 1
H
01
77
Thermal protection level
3
10~100%
1/1
100
Enabled
-
-
-
Ɣ
6. 4. 1
H
0178
Base frequency 4
25.0~
500 Hz
0.1/0.01
*
4
Disabled
-
-
-
Ɣ
6. 4. 1
H
0179
Base frequency voltage 4
50~330V/660V
1/0.1
*
3
Disabled
-
-
-
Ɣ
6. 4. 1
H
0180
Manual torque b
oost 4
0.0~30.0%
0.1/0.1
*
3
Enabled
-
-
-
Ɣ
6. 4. 1
H
0181
Thermal protection level
4
10~100%
1/1
100
Enabled
-
-
-
Ɣ
6. 4. 1
*1: For the adjustment range, see the table on page K-43.
*2: For the adjustment range, see the table on page K-45.
*3: Default values vary depending on the capacity. See the table of K-48.
*4: Inverter with a model number ending with -WN, HN: 60.0 -WP: 50.0
*5: Unsupported option