[Input terminal function setting (1/2)] Sensorless vector/vector with sensor (Ɣ: valid, -: invalid)
Positive
logic
Negative
logic
Function
Speed
control
Torque
control
PM control V/f EOQF= H= Reference
0 1 No function is assigned Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ - -
7.2.1
2 3 F: Forward run command Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ Ɣ -
4 5 R: Reverse run command Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ Ɣ -
6 7 ST: Standby Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1 -
8 9 RES: Reset Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2 -
10 11 S1: Preset speed 1 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
12 13 S2: Preset speed 2 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
14 15 S3: Preset speed 3 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
16 17 S4: Preset speed 4 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
18 19 Jog run Ɣ/Ɣ - Ɣ Ɣ Ɣ Ɣ
20 21 Emergency stop Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2 -
22 23 DC braking Ɣ/Ɣ - Ɣ Ɣ Ɣ Ɣ
24 25 Acceleration/deceleration switching 1 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
26 27 Acceleration/deceleration switching 2 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
28 29 V/f switching signal 1 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
30 31 V/f switching signal 2 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
32 33 Torque limit switching signal 1 Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ Ɣ -
34 35 Torque limit switching signal 2 Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ Ɣ -
36 37 PID control OFF selection Ɣ/Ɣ - Ɣ Ɣ Ɣ -
38 39 Pattern operation selection 1 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
40 41 Pattern operation selection 2 Ɣ/Ɣ - Ɣ Ɣ Ɣ -
42 43 Pattern operation continuation signal Ɣ/Ɣ - Ɣ Ɣ Ɣ -
44 45 Pattern operation trigger signal Ɣ/Ɣ - Ɣ Ɣ Ɣ -
46 47 External thermal error Ɣ/Ɣ - Ɣ Ɣ Ɣ -
48 49 Communication priority cancel Ɣ/Ɣ - Ɣ Ɣ Ɣ -
50 51
Holding of HD operation (stop of three-wire
operation)
Ɣ/Ɣ - Ɣ Ɣ Ɣ -
52 53 PID differentiation/integration reset Ɣ/Ɣ - Ɣ Ɣ Ɣ -
54 55 PID forward/reverse switching Ɣ/Ɣ - Ɣ Ɣ Ɣ -
56 57 Forced continuous operation Ɣ/Ɣ - Ɣ Ɣ Ɣ -
58 59 Specified speed operation Ɣ/Ɣ - Ɣ Ɣ Ɣ -
60 61 Acceleration/deceleration suspend signal Ɣ/Ɣ - Ɣ Ɣ Ɣ -
62 63 Power failure synchronized signal Ɣ/Ɣ - Ɣ Ɣ Ɣ -
64 65 My function RUN signal Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ Ɣ -
66 67 Auto-tuning signal Ɣ/Ɣ - Ɣ Ɣ Ɣ -
68 69 Speed gain switching Ɣ/Ɣ - Ɣ Ɣ Ɣ -
*1: Valid any time
*2: Independent of EOQF, and all command are valid.