3. Extended parameters
[1] Frequency signal Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Reference
Speed
control
Torque
control
H
0100
Low
-
speed signal output
frequency
0.0~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 1. 1
H
0101
Speed reach setting
frequency
0.0~WN Hz 0.1/0.01 0.0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 1. 2
H
0102
Speed reach detection
band
0.0~WN Hz 0.1/0.01 2.5 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 1. 2
[2] Input signal selection Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Reference
Speed
control
Torque
control
H
0105
Priority when
forward/reverse run
commands are entered
simultaneously
0:Reverse run
1:Stop
1/1 1 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 2. 1
H
0106
Input terminal priorit
y
selection
0:Disabled
1:Enabled
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 2. 2
H
0107 Unsupported
0:
-
1: -
2: -
3: -
4: -
5: -
6: -
7: -
8:
-
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *1
H
0108
Analog VI/II
voltage/current switching
0:Voltage input
1:Current input
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 2. 3
H
0109
Analog A
I
2 (optional
circuit board)
voltage/current switching
0:Voltage input
1:Current input
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 2. 3
*1: Unsupported option