Toshiba VF-AS1 Welding System User Manual


 
K-25
E6581301
11
[26] Override Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0660 Override addition input selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Operation panel input enabled (including
LED/LCD option input)
5:2-wire RS485 input enabled
6:4-wire RS485 input enabled
7:Communications option input enabled
8:Optional AI1 (differential current input)
9:Optional AI2 (voltage/current input)
10:Motor operated pot mop setting
11:Optional RP pulse input
12:Optional high-speed pulse input
13:-
1/1 0 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 34
H
0661
Override multiplication input
selection
0:Disabled, 1:VI/II, 2:RR
/S4
, 3:RX, 4:
H
,
5:
Optional
A
I
1
1/1 0 Enabled Ɣ/Ɣ - Ɣ Ɣ 6. 34
H
0665 Ground fault detection selection
0
:
D
etection
(except in stop)
1:No detection
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6.33.25
H
0669
Logic output/pulse output
selection (OUT1)
0:Logic output
1:Pulse output
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 35. 1
COUN
0670
AM terminal meter selection
0~6
4
*1
1/1
2
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
5. 16
This parameter moves to a fundamental parameter.
*1: For the adjustment range, see the table on page K-40.
[27] Meter output [1/2] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
CO
067
1
AM terminal meter adjustment
-
1/1
-
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
5. 16
H
0672
MON1 terminal meter selection
0~
76 *1
1/1
4
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
*2
H
0673
MON1 terminal meter
adjustment
- 1/1 - Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2
H
0674
MON2 terminal meter selection
0~
76 *1
1/1
5
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
*2
H
0675
MON2 terminal meter
adjustment
- 1/1 - Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2
H
0676
Pulse output function selection
0~
49 *1
1/1
0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 35. 1
H
0677
Selection of number of pulses
1.00~43.20kHz
0.01
/0.01
3.84
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 35. 1
H
067
8
Constant at the time of filtering
4msec, 8msec
~
100msec
1/1
64
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
5. 16
This parameter moves to a fundamental parameter.
*1: For the adjustment range, see the table on page K-39.
*2: For details, refer to Instruction Manual (E6581341) specified in Section 6.42.