Toshiba VF-AS1 Welding System User Manual


 
E6581301
A-6
1
M8 screw
Shorting-bar
Grounding capacitor switch
Grounding terminal
(M5 screw)
Screw hole for EMC plate
Grounding termin
al
(M8 screw)
Use crimped ring
lugs of appropriate
size on input and
output cables. Attach
to the top side of the
terminal block only.
Do not place wires
in the hole of the
terminal block.
A: -WN and –WP products.
B:
-
HN products only.
Insert the cables
(stripped the
appropriate length)
directly into the holes
in the front of the
power terminal block.
Tighten to
recommended torque
using the socket
head cap screw
provided in the
M12 screw
Shorting-bar
Grounding capacitor switch
Grounding terminal
(M8 screw)
Screw hole for EMC plate
Grounding termina
l
(M12 screw)
Use crimped ring
lugs of appropriate
size on input and
output cables. Attach
to the top side of the
terminal block only.
Do not place wires
in the hole of the
terminal block.
A: -WN and –WP products.
B:
-
HN products only.
Insert the cables
(stripped the
appropriate length)
directly into the holes
in the front of the
power terminal block.
Tighten to
recommended torque
using the socket
head cap screw
provided in the
terminal block.
Grounding terminal(M10 screw)
M12 screw
Grounding capacitor
switching bar
M10 screw
M8 screw
VFAS1-4300PL, 4370PL
VFAS1-2550P
VFAS1-4900PC
VFAS1-2300PM~2450PM
VFAS1-4450PL~4750PL