Toshiba VF-AS1 Welding System User Manual


 
E6581301
11
K-26
[27] Meter output [2/2] Sensorless vector/vector with sensor (Ɣ:Effective, -:Ineffective)
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Vector control
PM
control
V/f Constant
Reference
Speed
control
Torque
control
H
0681
FM voltage/current output
switching
0:Voltage 0~10
V
output
1:Current 0~20mA output
1/1 0 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 35. 3
H
0682
FM output gradient
characteristic
0:Negative gradient (descending)
1:Positive gradient (ascending)
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 35. 3
H
0683 FM bias adjustment -10.0~100.0% 0.1/0.1 0.0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 35. 3
H
0684 FM output filter
0:No filter
1:Filter approx. 10ms
2:Filter approx. 15ms
3:Filter approx. 30ms
4:Filter approx. 60ms
5:Filter approx. 120ms
6:Filter approx. 250ms
7:Filter approx. 500ms
8:Filter approx. 1s
1/1 0 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 5. 16
H
0685
AM output
gradient
characteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ 6. 35. 3
H
0686
AM bias adjustment
-
1
0.0~1
0
0.0%
0.1/0.1
0.0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
6. 35. 3
H
0688
MON1 voltage/current output
switching
0:Voltage
-
1
0~10
V
output
1:Voltage 0~10V output
2
:Current 0~20mA output
1/1 1 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2
H
0689
MON1 output gradient
characteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2
H
0690
MON1 bias adjustment
-
1
0.0~1
0
0.0%
0.1/0.1
0.0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
*2
H
0691
MON2 voltage/current output
switching
0:Voltage
-
1
0~10
V
output
1:Voltage 0~10V output
2
:Current 0~20mA output
1/1 1 Disabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2
H
0692
MON2 output gradient
characteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 1 Enabled Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ *2
H
0693
MON2 bias adjustment
-
1
0.0~1
0
0.0%
0.1/0.1
0.0
Enabled
Ɣ
/
Ɣ
Ɣ
/
Ɣ
Ɣ
Ɣ
*2
This parameter moves to a fundamental parameter.
*1: For the adjustment range, see the table on page K-40.
*2: For details, refer to Instruction Manual (E6581341) specified in Section 6.42.