ZyXEL Communications P-202 Router User Manual


 
P-202H Plus v2 Support Notes
Note: The IPSec policy is created with default IKE main mode (phase 1) on the
General tab. Please check details by clicking the Advanced on this tab.
The IPSec tunnel consists of two rules, each of which specifies a tunnel endpoint.
Because there are two endpoints so we need two filter rules. One is for the
direction from PC 1 to PC 2 (endpoint is P-202H Plus v2), and the other is from
PC 2 to PC 1 (endpoint is WIN2K). In each rule, a source IP and destination IP
for local and remote VPN clients (PC 1 or PC 2) are required. See the guides
below.
- Build a Filter List from PC 1 to PC 2
1. In policy properties, uncheck Use Add Wizard check box, and click Add
to create a new rule.