ZyXEL Communications P-202 Router User Manual


 
P-202H Plus v2 Support Notes
BACP negotiation started
IPCP up
LCP closed
IPCP closed
Recv'd TERM-ACK state 4
LCP stopped
P128> sys log disp
18 417888 PP0a ERROR Remote subnet mismatch, cfg'd 100.1.1.1
19 417889 PP0a ERROR neg'd 200.0.0.0
20 417892 PP0a WARN ip_route: code=05 P1=00 P2=00 P3=00
In this example, the IP address of the remote node is 100.1.1.1, but after PPP is
up, the far-end claims that their IP is in 200.0.0.0 network. P-202H Plus v2 will
drop the call, becuase of the IP address mismatch in this case.
Cannot answer incoming call from a Remote node or Dial-in User
The following are some of the possible reasons the P-202H Plus v2 not
answering an incoming call:
- System can't answer call
- ISDN protocol mismatched
- System authentication not set correctly
- Far-end name/password not correct
- IP address mismatched
To collect the trace or to identify the problem, just use 'sys event' command in
CI and wait for an incoming call. If it is a PPP related problem, then use the
following steps to collect PPP trace:
1. sys trcl cl
2. sys trcl sw on
3. sys trcp sw on
4. <Wait for an incoming call ( or issue 'sys event' ), after the call stops
>
5. sys trcl sw off
6. sys trcp sw off
7. sys trcl disp
All contents copyright © 2006 ZyXEL Communications Corporation.