Alignment Procedure
The alignment procedure that follows takes advantage of
Technobeam’s built-in program storage capability to turn the laser ON.
1. Follow the instructions in Chapter 1 to select a voltage setting and
install a power cord cap, if you have not already done so.
2. Physically orient the fixture as shown in Figure 6-25 (the farther away
the wall is, the more accurate your positioning will be):
Figure 6-25. Orient the fixture directly facing a wall no less than 10 ft. (3 m)
away.
3. Connect the fixture to an appropriately-rated power outlet. You will
hear sounds as wheels and motors seek their home positions;
this is
normal
.
4. When the fixture has finished homing, press and hold the <Menu> key
until the LED display reads
ADDR
.
The next steps show how to turn the lamp ON.
5. Use the <Up> and <Down> arrow keys to navigate to the
TEST
menu.
6. Press <Enter>, then use the <Up> and <Down> arrow keys to navigate
to the
LAMP
option.
7. Press <Enter>, then use the <Up> and <Down> arrow keys to select a
value of
ON
.
8. Press <Enter>; the lamp should now be on (although you will not be
able to tell if the dim flags are closed).
Stand fixture on its end handles
Sturdy, flat surface
such as a table
10 ft. (3 m) minimum
White wall