High End Systems Technobeam Work Light User Manual


 
Technobeam
®
User Manual Technobeam Laser Aiming Device™ 6-23
23. Make sure the fixture is oriented directly at the wall, not at an angle. If
the fixture is at an angle to the wall, it might be impossible to align the
laser properly.
24. Use the <Up> and <Down> arrow keys to navigate to the
TILT
option.
25. Press <Enter>, then use the <Up> and <Down> arrow keys to adjust the
mirror position until the beam is round.
26. Press <Enter> to accept your selection for TILT.
27. If the beam needs further adjustment, use the <Up> and <Down> arrow
keys to navigate to the
PAN
option.
28. Press <Enter>, then use the <Up> and <Down> arrow keys to adjust the
mirror position.
29. Press <Enter> to accept your selection for PAN.
30. Continue adjusting the mirror using PAN and TILT until the beam is as
round as possible.
If you cannot see the beam at all, the lamp might be off. Select
LAMP
from the Test menu and make sure a value of
ON
is displayed; see Step
5 through Step 8. (If the lamp still does not come on, wait a few
minutes and try again.)
31. Use the <Up> and <Down> arrow keys to navigate to the
FCUS
option.
32. Press <Enter>, then use the <Up> and <Down> arrow keys to focus on
the edge of the beam until it is sharp.
33. Continue moving the fixture and focusing on the edge of the beam
until the beam is as round as possible, and sharply in focus.
34. When you have focused the beam, press <Enter>.