Setting the Fixture Voltage
Technobeam is shipped from the factory set for 230V, 50Hz and offer
the following switch-selectable voltage/frequency settings:
230 V, 50 Hz 208 V, 60 Hz
100 V, 50 Hz 100 V, 60 Hz
120 V, 50 Hz 120 V, 60 Hz
The recommended fuse F3 for all voltages and frequencies is:
F3 -
250V, 6.3A, Slow Blow Only.
WARNINGS (1) Check the voltage setting before
proceeding with equipment setup!
(2) The information in this section is
intended to assist qualified service
personnel because this fixture is to be
serviced by qualified service personnel
only
.
(3) Disconnect power before re-lamping or
servicing.
(4) Replace fuses with specified type and
rating only.
1. Make sure the fixture is disconnected from the power outlet before
proceeding.
2. Lay the fixture on its back and locate the door retaining screw, as
shown in Figure 1-3. Loosen the screw and remove the access door.