High End Systems Technobeam Work Light User Manual


 
Technobeam
®
User Manual Menu Options 3-21
5. Press the <Enter> button to select the desired option.
Copying the Boot Code (BOOT)
When you upload new software to Technobeam-i fixtures, the new
software may contain a new boot code which must be copied to each
fixture. This is apparent if the LED displays a “BOOT DIFF” error.
Do
not remove power from the fixture while performing a boot copy
. You
can copy the new boot code using either the TEST menu or the SET
menu.
To accept and store the new boot code using the TEST menu:
1. Press and hold the <Menu> button until “ADDR” appears on the LED
display.
2. Using the <Up> and <Down> arrow buttons, scroll to the “TEST” menu
and press the <Enter> button to select the “TEST” menu.
3. Using the <Up> and <Down> arrow buttons, scroll to the “BOOT” option
and press the <Enter> button to select the “BOOT” option. The fixture
will store the new boot code, then automatically home.
Performing Self Tests (SELF)
This menu item performs the appropriate self tests for the following:
ALL - performs all of the self tests listed below
PAN - moves the pan motor from 0° to 180°
TILT - moves the tilt motor from 0° to 95°
COL - tests color wheel movement
LTO - tests litho wheel movement
FX - tests effects wheel movement
FCUS - tests lens tube movement
IRIS - tests iris movement
SHUT - tests shutter strobe functions
DIM - tests shutter dim flag movement
To perform a self test:
1. Press and hold the <Menu> button until “ADDR” appears on the LED
display.
2. Using the <Up> and <Down> arrow buttons, scroll to the “TEST” menu
and press the <Enter> button to select the “TEST” menu.
3. Using the <Up> and <Down> arrow buttons, scroll to the “SELF” menu
and press the <Enter> button to select the “SELF” menu.
4. Using the <Up> and <Down> arrow buttons, scroll to the desired option
(listed above). Press the <Enter> button to select the desired option.
The fixture will perform the selected self test.
5. Press the <Menu> button to exit the test.