9-3 Modbus - List of Parameters and Registers
This list is ordered alphabetically by the parameter name („Mnemonic“) column.
Any "#" is a wildcard, to be replaced by "1" or "2" for the desired measuring channel. In this case
the upper register line is assigned to channel 1, the lower line to channel 2.
Attribute
1
Daniel /
Enron
Modicon Type
Range / Enum values / Coefficients
Modbus-Register
Mnemonic
Description
3016 3016
AnalogAmplifierSettingDB
high/low analog amplifying is used
bit0 = high amplification Ch1
bit1 = high amplification Ch2
Cfg, Fac
Byte-Bitfield
3042
3044
3042
3044
AOutAdjustEnd#DB
Adjustment value for end of analog output
range
3300 .. 4050
Cfg,
Fac Int
3041
3043
3041
3043
AOutAdjustStart#DB
Adjustment value for begin of analog output
range
1500 .. 2500
Cfg,
Fac Int
9096
9098
6191..6192
6195..6196
AOutEndRange#DB
concentration level where the range of analog
output ends
min/max depend on EndOfRange#DB,
DifferentialMeasurementDB
Cfg
Float
3046 3046
AOutSignalAssignDB
Assignment of signals to the analog outputs
0 = AOut1-Comp1 AOut2-Comp2
1 = AOut1-Temp1 AOut2-Comp2
2 = AOut1-Comp1 AOut2-Temp1
3 = StartRange_ADJUST Aout#
4 = EndRange_ADJUST Aout#
Cfg, Fac
enum
9095
9097
6189..6190
6193..6194
AOutStartRange#DB
concentration level where the range of analog
output starts
min/max depend on EndOfRange#DB,
DifferentialMeasurementDB
Cfg
Float
3045 3045
AOutTypeDB
behavior type of the analog outputs
0 = 0 .. 20 mA (no Limits)
1 = 4 .. 20 mA (no Limits)
2 = 0 .. 20 mA (NE43; failure below)
3 = 4 .. 20 mA (NE43; failure below)
4 = 0 .. 20 mA (NE43; failure above)
5 = 4 .. 20 mA (NE43; failure above)
Cfg
enum
3100 3100
AutoCodeModeDB
defines how codes are automatically locked
again
0 = never
1 = on home key
2 = 1 minute after last key press
Cfg
enum
3006 3006
AutoZeroSpanTimeIntervalDB
time interval (in hours) for automatic zero&span
calibrations of both channels
0..999
Cfg
Integer
3005 3005
AutoZeroTimeIntervalDB
time interval (in hours) for automatic zero
calibrations of both channels
0..999
Cfg
Integer
3111..3114 3111..3114
BasicAccessCodeDB
user code for getting access to basic areas
2 characters per register:
1
st
character at HIGH byte,
2
nd
character at LOW b
y
te.
Cfg
String-8
3115 3115
BasicAccModeDB
mode for getting access to basic areas
0 = access is allowed
1 = access requires user code
2 = access is prohibited
Cfg
enum
3101 3101
BoardSerialNrDB
computer board serial number
Cfg, Fac
Word