Hitachi SJ300-037HFE Welding System User Manual


 
SJ300 Inverter
Configuring Drive
Parameters
3–65
“P” Group: Expansion Card Functions
The two (optional) expansion cards for the SJ300 have associated configuration data. The
following table defines the functions and their value ranges. Please refer to the expansion card
manual for more details.
“P” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)
P001 Operation mode on
expansion card 1 error
Two option codes:
00 Trip (stop motor)
01 Continuous operation
✘ ✔ 00 00 00
>P001 OPTION1
SELECT TRP
P002 Operation mode on
expansion card 2 error
Two option codes:
00 Trip (stop motor)
01 Continuous operation
✘ ✔ 00 00 00
>P002 OPTION2
SELECT TRP
P010 Feedback option enable Two option codes:
00 Disable
01 Enable
✘ ✘ 00 00 00
>P010 FEEDBACK
SELECT OFF
P011 Encoder pulse-per-
revolution (PPR) setting
Range is 128 to 65000
pulses per revolution
✘ ✘ 1024 1024 1024 pulse
>P011 FEEDBACK
ENC-P 01024pls
P012 Control pulse setting Selects between automatic
speed regulation (ASR) and
automatic position regula-
tion (APR) modes.
Two option codes:
00 ASR mode
01 APR mode
✘ ✘ 00 00 00
>P012 FEEDBACK
CONTROL ASR
P013 Pulse input mode setting Pulse input mode setting.
Three option codes:
00 quadrature
01 count and direction
02 separate forward and
reverse pulse trains
✘ ✘ 00 00 00
>P013 FEEDBACK
PULSE MD0
P014 Home search stop
position setting
Range is 0 to 4095 pulses ✘ ✔ 0. 0. 0.
>P014 FEEDBACK
POS 0000pls
P015 Home search speed
setting
Range is 0.00 to 99.99 /
100.0 to 120.0Hz
✘ ✔ 5.00 5.00 5.00 Hz
>P015 FEEDBACK
FC 005.00Hz
P016 Home search direction
setting
Two option codes:
00 Forward
01 Reverse
✘ ✘ 00 00 00
>P016 FEEDBACK
TURN FW
P017 Home search comple-
tion range setting
Range is 0 to 10,000 pulses ✘ ✔ 555pulse
>P017 FEEDBACK
L 00005pls
P018 Home search comple-
tion delay time setting
Range is 0.00 to 9.99
seconds
✘ ✔ 0.00 0.00 0.00 sec.
>P018 FEEDBACK
TW 000.00s
P019 Electronic gear set
position selection
Two option codes:
00 Position feedback side
01 Position command side
✘ ✔ 00 00 00
>P019 FEEDBACK
EGRP FB
P020 Electronic gear ratio
numerator setting
Range is 1 to 9999 ✘ ✔ 1. 1. 1.
>P020 FEEDBACK
EGR-N 00001
P021 Electronic gear ratio
denominator setting
Range is 1 to 9999 ✘ ✔ 1. 1. 1.
>P021 FEEDBACK
EGR-D 00001