To add a persistent binding:
1. In the Targets Table, click the target that you want to bind.
2. Click Add Binding. The Add Persistent Binding dialog box is displayed.
Figure 29: HBAnyware Utility, Add Persistent Binding Dialog Box
3. Select the Bind Type that you want to use (WWPN, WWNN or D_ID).
4. Select the Bus ID and Target ID that you want to bind, and click OK.
Note: All mapped targets, whether automapped or resulting from a persistent binding
configuration, will have entries in the “Current Mappings” table on the Target Mapping
dialog box.
If the binding that you defined has been successfully activated, you will see the
following message:
“The new binding has been created and is currently active.”
If, however, the binding was successfully created, but could not be made active, you
will see the following message:
“The new binding has been created. Note that this binding will not become active until
after you have rebooted the system.” Generally, you should ensure that the bind type
in the Current Settings section of the Target Mapping dialog box is the same as the
type of binding selected in the Persistent Binding Configuration section of the dialog
box.