Polycom 2000/4000 Saw User Manual


 
Chapter 17-RMX Administration and Utilities
17-14
NUMERIC_CONF_ID_
LEN
Defines the number of digits in the
Conference ID that will be assigned by the
MCU. Enter 0 to disable the automatic
assignment of IDs by the MCU and let the
Operator manually assign them.
Range: 2-16 (Default: 4).
NUMERIC_CONF_ID_
MAX_LEN
The maximum number of digits that the user
can enter when manually assigning an ID to a
conference.
Range: 2-16 (Default: 8)
Note: Selecting 2 limits the number of
simultaneous ongoing conferences to 99.
NUMERIC_CONF_ID_
MIN_LEN
The minimum number of digits that the user
must enter when manually assigning an ID to
a conference.
Range: 2-16 (Default: 4)
Note: Selecting 2 limits the number of
simultaneous ongoing conferences to 99.
NUMERIC_CONF_PASS
_MIN_LEN
Defines the length of the Conference
password.
Value: 0-16
0 - this rule is not enforced, however these
rules cannot be disabled when the RMX is in
Enhanced Security Mode.
In Enhanced Security Mode, Conference
password must be at least 9 characters in
length (default) and can be up to 16
characters in length.
PAL_NTSC_VIDEO_
OUTPUT
When set to AUTO (default), the video output
sent by the RMX is either in PAL or NTSC
format.
To force the RMX to send the video in either
NTSC or PAL, change the flag value
accordingly.
Default: AUTO.
Table 17-2 System Flags – MCMS_PARAMETERS (Continued)
Flag Description