DCS-100 • User’s Guide 137
_K==oÉãçíÉ=`çåíêçä
Remote Commands
f`mel
• Description: Input Phase Adjust. This command is only valid for analog input
types.
• Command Format: ICPHO -i (input) -a (ADC) -p (phase)
• Parameters: -i (input): 1 - 8 (7 & 8 only if itype is analog)
-a (ADC): A/B (A:ADC A, B:ADC B)
-p (phase): -16 - 15 (default: 0)
• Query Format: ICPHO -i (input) -a (ADC) -?
• Query Response: ICPHO -i (input) -a (ADC) -p (phase) --min -16 --max 15
f`ob`=
• Description: Recalls saved input configuration for selected input. The selected
input’s IMAP is updated if the -f (file) parameter is specified.
• Command Format: ICREC -i (input) -f (file)
• Parameters: -i (input):1 - 9
-f (file): 1 - 64. If specified, update the File Association menu to reflect the
selected file number.
• Query Format: ICREC -i (input) -?
• Query Response: ICREC -i (input) -f (file)
• List Format: ICREC -i (input) --list
The list returns all saved input formats.
• List Response:
1:"1"
2:"2"
.
.
64:"64"
f`opq
• Description: Reset Input Configuration to the input default values
• Command Format: ICRST -i (input)
• Parameters: -i (input): 1 - 9
• Query Format: N/A
• Query Response: N/A
f`p^s=
• Description: Saves the input configuration file. The input’s IMAP is updated if
the -f (file) parameter is specified. If the file parameter is not specified, the
command uses the current file number from the ICREC query.
• Command Format: ICSAV -i (input) -f (file)
• Parameters: -i (input):1 - 9