Barco DCS-100 Welding System User Manual


 
16 DCS-100 • User’s Guide
NK==fåíêçÇìÅíáçå
About the DCS-100
going out, and all analog outputs, plus the freeze and LOGO store
functions are disabled when the DCS-100 processes HDCP content.
Refer to the “A Word About HDCP” section on page 18 for more details.
~ 1080i RGB input is supported on the DVI digital input.
The following scaling and de-interlacing features are provided:
~ 10-bit scaling
~ 10-bit 4:2:2 de-interlacer with diagonal filter
~ 165MHz maximum pixel rate
~ Low video delay: Interlaced sources, 3 fields (max)
Stores and recalls up to three full screen logos. When a logo is on Program, it
appears visually on top of all other sources, including inputs with keys.
An Auto Take feature (in the User Preference Menu) supports transitioning from
one input source to another without pressing TAKE.
Provides the ability to luminance key unscaled DVI sources. Please note:
~ Keys are set up from the Key Menu. The front panel KEY button is used
to enable or disable the key transition.
~ Key transitions are performed at the same rate as the full screen source
transitions.
~ If the key source resolution is greater than the output resolution, the
DCS-100 only displays an area equal to the output resolution. This area
is selectable using the menu.
~ If the key source resolution is less than the output resolution, the key is
centered on screen, and can be moved within the screen boundaries.
Provides the ability to “auto acquire” input sources. The system monitors inputs at
all times, and if a timing change occurs, the system automatically reacquires and
displays the source — once the timing has been measured.
Offers simple and intuitive menus:
~ Presentations can be switched without accessing any setup menus.
~ Two front-panel lockout modes enable you to lock out menu access,
either completely or partially.
Provides an integrated test pattern generator.
Offers an HD/SD SDI input as standard.
Provides a built-in web-based GUI, which enables you to perform all setup and
transition functions, just like the front panel.
tÜ~íÛë=kÉï=áå=cáêãï~êÉ=sÉêëáçå=NKMP
This section lists the new or modified features that have been implemented since the last
revision of the DCS-100 User’s Guide. Reference links are provided for additional details.
File Association
The DCS-100 provides the ability to save and recall up to 64 input configuration
files. This library of configuration settings is stored in non-volatile memory and is
available for use by each of the nine inputs (1 through 8, plus SDI). Refer to the
File Association
” section on page 77 for detailed information about this feature.