76 DCS-100 • User’s Guide
4. Operation
Using the Setup Menu
If the programming is successful, the following message is displayed:
Figure 4-44. Programming EDID Message 2
If the EDID programming failed, the following message will be displayed:
Figure 4-45. EDID Programming Failed Message
If this message persists, please contact customer service for technical support.
Type (7, 8) — This field applies to inputs 7 and 8 only, allowing you to select
between Digital or Analog EDID for these inputs. Please note:
~ When the Input field is set to inputs 1 - 6, the Type field shows
[ANALOG], and cannot be changed.
~ When the Input field is set to 7 or 8, the Type field is selectable between
ANALOG or DIGITAL, and the current Type is reflected. Changing this
field triggers the programming process as soon as SEL is pressed, using
the currently shown resolution in the Format field.
~ When ALL is selected in the Input field, the Type field reflects Input 7.
Any triggering of the programming process changes both inputs 7 and 8
to the selected option in this field.
EDID Prog Done
Connect DVI inputs
and reboot the PC
ESC = Continue
Note
At this point, reboot the external computer(s) in order for the
new EDID information to be read, and the new preferred
resolution to become available.
EDID Prog failed!
ESC = Continue