Barco DCS-100 Welding System User Manual


 
DCS-100 • User’s Guide 153
_K==oÉãçíÉ=`çåíêçä
Remote Commands
hÉó=`çãã~åÇë
ihbv=
Description: Luminance Key definition
Command Format: LKEY -m (mode) -s (source) -c (clip) -g (gain) -o (opacity) -h
(hoffset) -v (v offset)
Command Params:
-m mode: 0-off, 1-on (Default: off)
-s source: 1-6 (analog) 7-8 (DVI), 9-SDI
-c clip: 0 - 1023 (default: 0)
-g gain: 0 - 1023.99 (default: 1.00)
-o opacity: 0-1023 (default: 1023)
-h hoffset: +/- ½ (input hact - output hact)
-v voffset: +/- ½ (input vact - output vact)
Query Format: LKEY -? -(option letter)
The LKEY query will return only one option parameter at a time. If no
option is specified, an error code will be returned.
Query Response: LKEY -m (mode) --min 0 --max 1
LKEY -s (source) --min 0 --max 11
LKEY -c (clip) --min 0 --max 1023
LKEY -g (gain) --min 0 --max 1023.99
LKEY -o (opacity) --min 0 --max 1023
LKEY -h (hoffset) --min (hoffset min) -max (hoffset max)
LKEY -v (voffset) --min (voffset min) -max (voffset max)
List Format: LKEY --list
The list command for LKEY returns the possible values for the source
parameter.
List Response: 1:"1"
2:" 2"
3:"3"
4:"4"
5:"5"
6:"6"
7:"7"
8:"8"
9:"SDI"