142 DCS-100 • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
fpif`b=
• Description: Input Sync Slice Threshold Adjust. This command is only valid for
analog inputs.
• Command Format: ISLICE -i (input) -t (threshold)
• Parameters: -i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog)
-t(threshold): 8 - 256mV; +8 increments (default: 128mV)
• Query Format: ISLICE -i (input) -?
• Query Response: ISLICE -i (input) -t (threshold) --min 8 -- max 256
fpjm=
• Description: Adjust Input Sample mode. This command is only adjustable for
analog input types. Other input types will provide query information only
• Command Format: ISMP -i (input) -s (sample mode)
• Parameters:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for
query
-s (sample mode): 0 - over sample, 1 - 1:1 sampling (Default: 1:1)
• Query Format: ISMP -i (input) -?
• Query Response: ISMP -i (input) -s (sample mode) --min 0 -- max 1
• List Format: Each input type has a different list of valid sample modes.
ISMP -i (input) --list
• List Response: 0:"OverSample"
1:"1:1"
fpvk`
• Description: Input Sync Type Adjust. This command is only valid for analog
input types.
• Command Format: ISYNC -i (input) -s (sync)
• Parameters: -i (input): 1 - 8 (7 & 8 only if itype is analog)
-s (sync): 0 - auto, 1 - H/V, 2- CSync, 3- SOG (Default: auto)
• Query Format: ISYNC -i (input) -?
• Query Response: ISYNC -i (input) -s(sync) --min 0 --max 3
• List Format: ISYNC -i (input) --list
• List Response: 0:"AUTO"
1:"H/V"
2:"CSYNC"
3:"SOG"