Barco DCS-100 Welding System User Manual


 
DCS-100 • User’s Guide 139
_K==oÉãçíÉ=`çåíêçä
Remote Commands
fem^k=
Description: Input Horizontal Pan
Command Format: IHPAN -i (input) -p (pan)
Parameters:
-i (input): 1 - 9
-p (pan): In pixels
Query Format: IHPAN -i (input) -?
Query Response: IHPAN -i (input) -p (pan) --min (active min) -- max (active
max)
femlp
Description: Input Horizontal Position Adjust. This command is only adjustable
for analog input types. Other input types will provide query information only.
Command Format: IHPOS -i (input) -p (position)
Parameters:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for
query
-p (position): In pixels
Query Format: IHPOS -i (input) -?
Query Response:
IHPOS -i (input) -p (position) --min (pos min) -- max (pos max)
feqlq^i
Description: Input Horizontal Total Adjust. This command is only adjustable for
analog input types. Other input types will provide query information only.
Command Format: IHTOTAL -i (input) -t (total)
Parameters:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for
query
-t(total): In pixels
Query Format: IHTOTAL -i (input) -?
Query Response: IHTOTAL -i (input) -t (total) --min (total min) -- max (total max)
Query Response:
IHATV -i (input) -a (active) --min (active min) -- max (active max)
ferb
Description: Input Hue Adjust. This command is only valid for SDI, Y/C and
CVBS inputs.
Command Format: IHUE -i (input) -h (hue)
Parameters:
-i (input): 1 - 9