Barco DCS-100 Welding System User Manual


 
78 DCS-100 • User’s Guide
4. Operation
Using the Setup Menu
You can view and change the current setting for each input by using the File Association
Menu, shown in the following illustration.
Figure 4-47. File Association Menu (sample)
When you associate a configuration file with a specific input, the file is used by any input
source connected to that input.
To change a setting, scroll to an input number and press SEL. Choose a new configuration
file and press SEL again. The change takes effect the next time the input button is
pressed.
Refer to the “About Input Configuration Files” section on page 61 for additional
information about setting, recalling, saving and deleting input configuration files.
qÉãéÉê~íìêÉ
From the System Menu, select Temperature to display the System Temperature Menu.
Figure 4-48. System Temperature Menu (sample)
The System Temperature Menu indicates the chassis’ internal temperature in both celsius
and farenheit. When the menu is displayed, temperature values update every 4 seconds.
Note that the DCS-100 measures the internal temperature for an “over-temp” condition
every 5 minutes. If the system’s internal temperature exceeds 122° F (50° C), the following
message appears:
Figure 4-49. Over Temperature Warning (sample)
FILE ASSOCIATION
> Input 1 1
Input 2 2
Input 3 3
Input 4 4
Input 5 5
Input 6 6
Input 7 7
Input 8 8
SDI 9
SYSTEM TEMPERATURE
Temperature °F 85.8
Temperature °C 29.9
OVER TEMPERATURE
Contact factory if
condition persists.
ESC = Continue