Barco DCS-100 Welding System User Manual


 
72 DCS-100 • User’s Guide
4. Operation
Using the Setup Menu
Diagnostics
Save System State
sca=_êáÖÜíåÉëë
From the System Menu, select VFD Brightness to control the intensity of the front panel
VFD (vacuum fluorescent display).
Adjustment range: 1 - 16 (1 is the dimmest setting)
Default: 10
bíÜÉêåÉí
From the System Menu, select Ethernet to display the Ethernet Menu:
Figure 4-36. Ethernet Menu (sample)
The following Ethernet functions are available:
DHCP — DHCP can be turned OFF or ON.
~ When OFF, the Config Network field appears, which enables you to
manually enter a static IP address, Subnet mask and Gateway.
~ When ON, the DCS-100 queries the DHCP server for a valid IP address,
and the Config Network field is hidden.
If the DCS-100 finds a DHCP server and receives an IP
address, the address is displayed.
If a server is not found, an IP address is not assigned.
Config Network — select this function to display the Config Network Menu,
which enables you to choose the specific Ethernet address you wish to change.
Figure 4-37. Config Network Menu
Note
It is recommend that you use a low intensity setting to avoid
"burn-in" of the display.
ETHERNET
> DHCP OFF
Config Network >>
IP 192.168.000.010
M 00:04:a5:19:10:52
Note
Always consult with your network administrator to obtain valid
IP, subnet mask and gateway addresses.
CONFIG NETWORK
> Set Static IP >>
Set Netmask >>