Lincoln Electric SVM200-A Welder User Manual


 
FIGURE F.41 – VR SMAW DEVICE LOCATION
VR SMAW (STICK) DEVICE
REMOVAL AND REPLACEMENT PROCEDURE (continued)
REMOVAL PROCEDURE
1. Remove input power.
2. Perform the Monitor and Pedestal Removal
Procedure.
3. Perform the Case Cover Removal Procedure.
4. Locate the VR SMAW Device. See Figure F.41.
5. Disconnect plug J3 from the relay board. See
Figure F.22.
6. Using the 3/8” wrench, remove the two screws
holding the sheet metal strain relief to the front
panel. See Figure F.42.
7. Locate and disconnect the 16 pin molex style
cable splice. See wiring diagram.
TROUBLESHOOTING AND REPAIR
F-90 F-90
VRTEX
TM
360
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC