Lincoln Electric SVM200-A Welder User Manual


 
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
CAUTION
The weld coupon image is a
different configuration than the
physical coupon.
Either the wrong coupon is on
the stand or the wrong
configuration as been selected
in the software.
Press the menu button and
select change coupon type.
Change the software selections
so that the images on the
screen match the hardware you
are using.
N/A
The arm and/or table are different
than the visuals in the software.
The software information may
be incorrect. Press the menu
button and select change
process. Make sure the images
on the screen match the
hardware being used.
N/A
When the check settings are
activated the incorrect settings
appear.
Check the settings in the
Instructor Mode.
Make sure all of the settings are
correct for the process and
parameters being used. Check
for the acceptable ranges for the
Lincoln defaults.
N/A
TROUBLESHOOTING AND REPAIR
F-12 F-12
VRTEX
TM
360
Holding the green button in does
not shut down the VRTEX
TM
360
To shut down the VRTEX
TM
360
select menu and then select
shutdown.
N/A
Sometimes the view in the helmet
seems to shake, wobble or jitter.
Make sure the helmet is close to
the work piece. The further the
helmet is from the work piece
the more jitter there may be in
the helmet display. Also make
sure there are not other objects
or frequencies that are
interfering with the system.
See the Installation Section of
this manual.
Check for loose or faulty
connections on the VGA cable
between the Relay Board and
the Polhemus Interface Module.
See the wiring diagram.
Perform the Polhemus
Interface Module Test.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC