Lincoln Electric SVM200-A Welder User Manual


 
OPERATION
B-13 B-13
VRTEX
TM
360
Weld Machine Settings Screen:
Overview
The user must enter the proper welding procedure
and process settings, including wire feed speed,
amperage, voltage, and polarity, where applicable. As
in the gas setup screen, the user must enter values
within the acceptable range as governed by the toler-
ance editor. If not, they will be notified when the
green check settings button is pressed by the incor-
rect weld setting screen.
The user changes the wire feed speed or amperage
by rotating the wire feed speed/amperage dial. The
display above the dial indicates the setting.
The user changes the voltage by rotating the voltage
dial. The display above the dial indicates the setting.
Some processes may not allow the user to pre-set the
voltage, in which case the display will be blank.
WELD MACHINE SETTINGS SCREEN
THE INCORRECT WELD SETTINGS SCREEN
Menu
Selecting Logout brings the user back to the login
screen, with the userʼs name removed.
Back
Pressing Back goes back to the previous screen.
Virtual Welding Overview
While a user is welding, observers can see the
Welderʼs view, LASER screen, or Instructorʼs view dis-
played on the monitor. The Welderʼs view shows the
helmets point of view. The LASER screen displays a
real time graph of the weld being made and gives a
score when the user selects “end pass”. The
Instructorʼs view allows another user to zoom in/out
and rotate the coupon to view the weldment from dif-
ferent angles in real time.
Polarity Selector
Change the polarity by rotating the polarity selector
switch. The user can select the following:
• AC
• DC+
• DC-
If default tolerances are being used, refer to the
Default Weld Process Settings included in this
manual.
Once the user has set the welding parameters, they
should press the green check settings button. If the
user has entered any settings outside the acceptable
range specified by the settings in the tolerance editor,
the incorrect weld setting screen will appear. The user
will then have to change any settings that are not cor-
rect. If the settings are correct and the green check
settings button is pressed, the selected environment
screen will appear on the monitor and in the helmetʼs
stereo visor. The user will then be able to start virtual
welding.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC