TROUBLESHOOTING AND REPAIR
F-9 F-9
VRTEX
TM
360
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The user is not receiving any
visual or audio feedback
information in the helmet (FMD).
Make sure the Helmet (FMD) is
connected properly.
Check the USB connection
between the Polhemus Interface
Module and the CPU for loose
or faulty connections.
Check the USB connections
between the Polhemus
Interface Module and the CPU
for loose or faulty connections.
Make sure the FMD Control
Unit is are receiving the 5VDC
supply voltage. See the wiring
diagram.
Make sure the FMD Control
Unit is turned on.
If the 5VDC supply is not
present perform the 5VDC
Supply Test.
Perform the FMD Control Unit
Test.
The FMD may be faulty.
The CPU may be faulty.
Check for loose or faulty con-
nections (ribbon cable)
between the User Interface
Digital I/O Module and the ter-
minal block interface. See
wiring diagram
(Continued)
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC